Transportation
10
Mains connection
The machine complies with the requirements of EN / IEC
61000-3-12 provided that the maximum network impedance
Zmax is smaller or equal to the impedance Zmax of the machi-
ne at the connecting point to the public low-voltage network
specified in the technical specifications. The fitter or user of
the machine is responsible to ensure that, where applicable
by coordination with the public power supplier, the machine
is only connected to a public low-voltage network when the
maximum network impedance Zmax is smaller or equal to the
impedance Zmax of the machine specified in the technical
specifications.
WARNING: Permanent use of the machine at maximum per-
formance with an actual switching period that is greater than
fifteen percent leads to the limit values for Rsce defined ac-
cording to IEC 61000-3-12 being exceeded, If the machine is
to be operated with a respectively high loading on a public
low-voltage network, the permission of the power supplier
must be obtained by the user with regard to the connection
of the device.
11
Transportation
For transport using mechanical lifting
equipment (e.g. crane, ...) only the handle
may be used as the hoisting point. Use sui-
table load-carrying equipment. Do not lift
the machine from the housing using a fork
lift or similar equipment. The carrying strap
is exclusively for the transport by a person.
01.22