Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SINAMICS DCM Betriebsanleitung Seite 471

Sinamics drives cabinet
Vorschau ausblenden Andere Handbücher für SINAMICS DCM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Order number 6RM80..
Armature circuit short-circuit current
capability
Power loss at rated DC current (ap-
prox.)
Maximum permissible protection
on the customer's side (LV h.b.c. fuse
gL/gG)
Armature circuit DC connection
Rated DC voltage
1)
Rated DC current
Rated power
Field circuit
Rated DC voltage
1)
Rated DC current
Auxiliaries power connection
Rated supply voltage
1)
Auxiliary supply
short-circuit current capability
Current demand
3)
Maximum permissible protection
on the customer's side
Motor fan
Rated supply voltage
Setting range of the
motor circuit breaker
Cabinet cooling
Type of cooling
Fan air flow
Fan noise level
Cabinet
Frame size
(dimensions, see Chapter Design
(Page 22))
Weight without options (approx.)
Connection: Connection point, connection system, connection cross-section
for tightening torques, see tables.
1U1, 1V1, 1W1
AC armature without filter
1U1, 1V1, 1W1
AC armature with filter
1C1, 1D1
SINAMICS DCM Cabinet
Operating Instructions, 04/2015, A5E36161239/RS-AA/001
..86-6KS22
kA
50
W
4012
A
630
V
830
A
720
kW
598
V
390
A
30
V
2-ph 480 V AC (+10% / 20%), 50 Hz
kA
30
A
A
63
3-ph 400 V AC, 50 Hz / 3-ph 460 V AC, 60 Hz
A
7 to 10
Device fan
m
/h 800
3
dBA
64.5
DC
kg
515
Incoming feeder
circuit breaker,
800 A with fuses
Terminal end
2x240 mm², M12
Customer
connections
2x240 mm², M12 4x120 mm², M12
SINAMICS DCM DC Converter
10.3 Technical specifications
..90-6KS22
65
4642
5)
1000
830
390
30
30
63
11 to 16
Device fan
1000
66
DC
600
Customer
connections
Terminal end
4x120 mm², M12
Customer
connections
Technical specifications
159

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis