Herunterladen Inhalt Inhalt Diese Seite drucken

B62, Display Instrument "Armature Current - Siemens SINAMICS DCM Betriebsanleitung

Sinamics drives cabinet
Vorschau ausblenden Andere Handbücher für SINAMICS DCM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Options
11.4 Display instruments
11.4.3

B62, display instrument "armature current"

Category
Display instruments
Function
Analog display instrument, door mounting, black front frame, 96 × 96 mm, scale 0 to 200 %
for two-quadrant units and ± 200 % with center zero point for four-quadrant units. The
measured value is provided via an analog output of the SINAMICS DCM DC Converter.
Note
A maximum of six display instruments can be ordered for various display values. From a
total of three display instruments (B60, B61, B62, B64), option G60 must also be ordered.
Connection
Is connected up in the manufacturer's factory.
Commissioning
The analog output actually used depends on the combination of the selected options, and
must be taken from the circuit diagram on a project for project basis. According to the
project-specific solution, the parameter assignment should be defined using the operating
instructions for the SINAMICS DCM DC Converter and the List Manual, and should be
parameterized and tested during the commissioning phase.
Parameter assignment
Interconnect connector r52109 to the analog output.
Scaling of p52109: 100 % corresponds to p50072[1]
The scaling must be performed corresponding to the end of scale value of the measuring
instrument.
The analog output intended for this function must be parameterized on a project-for-project
basis.
220
Operating Instructions, 04/2015, A5E36161239/RS-AA/001
SINAMICS DCM Cabinet

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis