Electrical installation
4.9 Signal connections
Table 4- 7
X71 / X72 assignment (2nd block)
Terminal
Function
Serial interface, peer-to-peer RS485
35, 36
MDIG
Ground, digital
37
TX+
Send cable +
38
TX-
Send cable -
39
RX+
Receive cable +
40
RX-
Receive cable -
Incremental encoder input
41
Incremental encoder supply
42
Incremental encoder ground
43
Track 1 positive connection
44
Track 1 negative connection
45
Track 2 positive connection
46
Track 2 negative connection
47
Zero mark positive connection
48
Zero mark negative connection
Analog outputs (assignable outputs)
49
AO 0
Analog output 0
50
MANA
Ground, analog
51
AO 1
Analog output 1
52
MANA
Ground, analog
Connections for temperature sensor (motor interface 1)
53
Temp 1
54
Temp 2 (sense cable)
55
Temp 3
Terminals for ground and 24 V DC supply
56
MANA
Ground, analog
57, 58, 59,
24 V D
24 V supply (output)
60
C
61, 62, 63,
MDIG
Ground, digital
64
90
Technical data
4-wire send cable, positive differential output
4-wire send cable, negative differential output
4-wire receive cable, positive differential output
4-wire receive cable, negative differential output
+13.7 to +15.2 V, 300 mA short-circuit proof (electronically protected)
If overload occurs: alarm A60018
Load: ≤ 5.25 mA at 15 V (without switching losses)
Pulse duty factor: 1:1
For information on cables, cable length, shield support, input pulse
levels, hysteresis, track and pulse frequency, see SINAMICS DCM
DC Converter Operating Instructions
±10 V, max. 2 mA short-circuit proof, resolution ±15 bits
Sensor acc. to p50490 (refer to SINAMICS DCM List Manual)
The cable to the temperature sensor on the motor must be shielded
and connected to ground at both ends.
The cables for the Temp 1 and Temp 3 connections to the
temperature sensor must be approximately the same length.
The sense cable (Temp 2) is used for compensating the
cable resistances. If you are not using a sense cable, terminals 54
and 55 must be connected.
Connection without/with sense cable:
24 V DC, short-circuit proof
Max. load 200 mA (terminals 9, 10, 57, 58, 59 and 60 combined),
internal supply to digital ground and analog ground
Operating Instructions, 04/2015, A5E36161239/RS-AA/001