11.4 Display instruments

11.4
Display instruments
11.4.1

B60, display instrument "speed"

Category
Display instruments
Function
Analog display instrument, door mounting, black front frame, 96 × 96 mm, scale 0 to ±125 %
with center zero point. The measured value is provided via an analog output of the
SINAMICS DCM DC Converter.
Note
A maximum of six display instruments can be ordered for various display values. From a
total of three display instruments (B60, B61, B62, B64), option G60 must also be ordered.
Connection
Is connected up in the manufacturer's factory.
Commissioning
The analog output actually used depends on the combination of the selected options, and
must be taken from the circuit diagram on a project for project basis. According to the
project-specific solution, the parameter assignment should be defined using the operating
instructions for the SINAMICS DCM DC Converter and the List Manual, and should be
parameterized and tested during the commissioning phase.
Parameter assignment
Interconnect connector r52167 to the analog output.
The analog output intended for this function must be parameterized on a project-for-project
basis.
Normalization: 10 V at the analog output corresponds to 125 % of r52167
218