Herunterladen Inhalt Inhalt Diese Seite drucken

Configuration Of The Integrated Inverter; Priming - DAB ESYBOX MAX 60/120M Installations- Und Wartungsanleitungen

Vorschau ausblenden Andere Handbücher für ESYBOX MAX 60/120M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 124
The appliance must be connected to a main switch that cuts off all the power supply poles. When the switch is in off position, the distance
separating each contact must respect the indications in table 3.
The cable gland, supplied with the terminal box, binds the outer diameter of the cable sheath in a range between 7 and 13mm. The mammoth
terminal block can accommodate cables with a lead cross-section up to 2.5mm2 (AWG14 for USA versions).

6.2 Configuration of the Integrated Inverter

The system is configured by the manufacturer to satisfy the majority of installation cases, that is:
operation at constant pressure;
Set-Point (desired value of constant pressure):
Reduction of pressure to restart:
Anti-cycling function:
However, all these parameters can be set by the user (see the chapter Settable parameters)
The system does not work if the utility is at a height higher than the equivalent in metres of water column of the Pstart (consider 1 bar = 10 m.
water column): for the default configuration, if the utility is at a height of at least 27m the system does not start.

6.3 Priming

For the first start-up, follow the steps below:
Make the hydraulic and electrical connections (without supplying power)
Fig 11 example of single-phase installation
Fig 12 example of three-phase installation
Minimum distance between the contacts of the power switch
Minimum distance [mm]
ENGLISH
>3
Table 3
SP = 3.0 bar
RP = 0.3 bar
Disabled
50

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Esybox max 60/120tEsybox max 85/120t

Inhaltsverzeichnis