EtherCAT® data transmission and configuration
90
The value 0 has a special function for the selection. As
soon as the working parameter set is changed, but not
yet saved under a valid parameter number, no parameter
set number will exist for the working parameter set and 0
is then returned.
Bit 7 in the parameter set (locked bit) has the following
function.
Bit 7 signals the EtherCAT
to the parameter selection as it is currently being edited
in the web browser (Ethernet). The measured values con
tinue to be sent to the EtherCAT
Notice
Editing in the web browser has a real-time effect on the
bus and the measured value.
A3704-4.0 HBM: public
®
master that it has no access
®
bus.
TIM-EC