Type
Linearization for full range 1:1 and partial
range 1:5 or 1:10 (right, left, up to
11 points)
Maximum cable length for TIM-EC
torque transducer
Rotational speed
Input signal
Signal type
Data rate
Measuring range of pulse frequency meas
urement
Resolution
Frequency measurement resolution, min.
Measuring range 20 kHz
Measuring range 200 kHz
Measuring range 1000 kHz
Accuracy
Frequency measurement rel. to act.
value
Temperature effect per 10K, rel. to
act. value
Internal sampling rate
Input filter / glitch filter time constant
(adjustable)
Low pass filter, 4th order
Runtimes of filters 1 and 2
Filter off
3000 Hz
1000 Hz
TIM-EC
m
Hz
bits
mHz
mHz
mHz
%
%
MHz
Hz
μs
μs
μs
A3704-4.0 HBM: public
TIM-EC
Calibration coefficients can be
entered directly
50
Quadrature / single /
direct for T40 family
RS422
approx. 39000
Determined automatically from max.
rotational speed and pulses/revolu
tion of the transducer
25
10
125
≤0.01
≤0.01
125
80 ns / 800 ns / 8 ms / 80 ms
0.1 / 1 / 10 / 100 / 1000 / 3000 / Off
0.944
54.4
212
Specifications
1
109