Technical Data
Maximum obstacle 
height
Approx. distance 
range
Operating temperature 
range
Transport and storage 
temperature range
Battery charger
Model
Power requirements
Mains frequency
Protection class
Charging connection
Nominal charging 
current
Residual ripple
Characteristic 
charging curve
Page 184
160 kg: Caster axle ahead  
             10 cm
160 kg: Drive axle ahead  
             14 cm
60 km
-25 °C to +50 °C
-40 °C to +65 °C
Mentzer G3-424-20
Automatic battery charger 
with computer-controlled 
characteristic curve
230 V ±15 %
50 / 60 Hz ±4 %
1 (protective conductor)
24 V DC
20 A
<1 %
IUoU, characteristic curve 
analogue to DIN 41773
Primary fuse
Secondary circuit 
breaker
Protection type
Ambient temperature 
range
Display
Weight
Dimensions (W x H x D)
Tab. 9
Technical data
01 / 2010
T6 G fuse link, 3 A, not 
accessible from outside
Electronic, reversible reverse 
battery protection, short-circuit-
proof, idling-proof, overheating 
protection
IP 21
-10 °C to +40 °C
3 LEDs
1.9 kg
290 x 150 x 95 mm