EN 52
8.15 Maintenance table
Several times per day
Task
Checking the external compressed
air lines for damage
Checking the suction hose for
damage
Once per day
Task
Checking the compressed air regu-
lator
(
)
page 45
Daily cleaning of the working
chamber
(
)
page 42
Once per week
Task
Cleaning the collet chuck
(
)
page 43
When necessary
Task
Updating the software and firm-
ware
(
)
page 51
Additional cleaning of the working
chamber
(
)
page 42
Cleaning the housing
(
)
page 46
Exchanging the main fuse
(
)
page 46
Replacing the clamping system of
the blank holder
(
)
page 49
Recommended interval
Before switching on the
machine
Before switching on the
machine
Recommended interval
Before work
Clean or exchange cartridge
in case of visible contam-
ination or every 2 years
After work
If soiled
Recommended interval
Once per week
In case of rotational imper-
fections
Recommended interval
When an update is available
When the webcam is soiled
When the view window is
soiled
Original Operating Instructions: K5+
Version: 12/16/2021
K5+ – Maintenance and do-it-yourself
Procedure / Parts
Visual check
Visual check
Procedure / Parts
If necessary, new filter cart-
ridge
Vacuum cleaner, Brush, Dry
cloth
Procedure / Parts
Spindle service set
Procedure / Parts
Dry cloth
Microfiber cloth, Water, Mild
cleaning agent (optional)
Replacement fuse T6,3A
L250V
Clamping system blank holder
Tool illustration
Tool illustration
Tool illustration
Spare part illustration