Operating instructions CNC 4.0 400/500/630
Caution
13 Maintenance
The CNC 4.0 400/500-630 should be checked and cleaned periodically.
Normal care of the machine is limited to periodic cleaning of the
outside.
The complete machine with all components should be maintained and
calibrated at a certified Georg Fischer service station every 3200 hours
of use or after 2 years.
13.1
Replacement of worn parts
PTFE coating of the heating element:
Clots, cracks or other damage:
– heating element needs to be recoated.
– send the heating element to the nearest service center or to the
manufacturer.
Planer blades:
The planer blades on the planer should be replaced periodically.
For order number see spare parts list.
Danger of injury!
Danger of cutting if the planer blades, which are sharp on both sides,
are touched.
13.2
Hydraulic system
The hydraulic connections on the machine and on the hydraulic unit
need regular cleaning.
When not in use, the hydraulic connections on the GF base machine
should be protected with the protective caps.
13 Maintenance