Herunterladen Inhalt Inhalt Diese Seite drucken

GF CNC 4.0 400 Betriebsanleitung Seite 83

Stumpfschweissmaschine
Vorschau ausblenden Andere Handbücher für CNC 4.0 400:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating instructions CNC 4.0 400/500/630
Message
AMBIENT
TEMPERATURE
TOO HIGH
CONNECT
POTENTIOMETER
AND RESTART
BASE MACHINE
NOT CONNECTED
CONNECT
POTENTIOMETER
AND RESTART
HEATING ELEMENT
NOT CONNECTED
CONNECT
HEATING ELEMENT
AND RESTART
Display page
Meaning
Dedicated
Measured
page.
ambient
temperature
too high.
It's not possible
to proceed
with welding
Dedicated
page.
potentiometer
detected.
It's not possible
to proceed
with welding
Dedicated
No heating
page.
element
detected.
It's not possible
to proceed
with welding
Possible causes
1) Potentiometer
not
connected to
the hydraulic
unit
2) Potentiometer
cable
process.
damaged
3) Temperature
probe /
temperature
board failure.
No
1) Potentiometer
not
connected to
the hydraulic
unit
2) Potentiometer
process.
cable
damaged
4) Potentiometer
/ temperature
board failure.
1) Heating
element not
connected to
the hydraulic
unit
3) Temperature
process.
probe /
temperature
board failure
12 Error/Warning messages
Actions
1) Connect
potentiometer
and re-start the
machine.
2) Change the
cable and re-
start the
machine.
3) Get in contact
with a certified
Georg Fischer
service station.
1) Connect
potentiometer
and re-start the
machine.
2) Change the
cable and re-
start the
machine.
4) Get in contact
with a certified
Georg Fischer
service station.
1) Connect
heating element
and re-start the
machine.
3) Get in contact
with a certified
Georg Fischer
service station.
77

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cnc 4.0 500Cnc 4.0 630

Inhaltsverzeichnis