Operating instructions CNC 4.0 400/500/630
Message
BAR CODE PIPE L/R
ERROR
Open the carriage!
PIPE POSITION
NOT CORRECT
Reduce pipe
distance!
PIPE POSITION
NOT CORRECT
Increase pipe
distance!
Display
Meaning
page
Dedicated
The pipe /
page.
fitting bar
code doesn't
correspond to
ISO 12176-4.
CLAMP
Base machine
PIPES AND
carriage is not
CHECK
completely
ALIGNMENT
open.
It's not possible
to get the next
process step.
Dedicated
Not enough
page.
pipe material
to grant
welding.
It's not possible
to get the next
process step.
Dedicated
Not enough
page.
space to insert
the facer.
It's not possible
to get the next
process step.
12 Error/Warning messages
Possible causes
Pipe / fitting
barcode is wrong
or barcode reader
has not been
properly pointed
at barcode
symbol.
1) The carriage is
not in the
completely
open position
2) Obstacles to
pipe
movement.
3) Potentiometer
error.
1) Pipes are not
correctly
positioned into
claps
2) Potentiometer
error.
1) Pipes are not
correctly
positioned into
claps
2) Potentiometer
error
Actions
Check the bar
code and then
push the ◄ button
to proceed again
with scanning.
1) Push ◄►
button to open
2) Check if pipes
are properly
supported and
aligned.
3) Calibrate the
potentiome-ter
(see chapter
9.3.1).
1) Adjust the pipes
position.
2) Calibrate the
potentiome-ter
(see chapter
9.3.1).
1) Adjust the pipes
position
2) Calibrate the
potentiome-ter
(see chapter
9.3.1)
79