4.8 Scope of delivery

Standard items
• Unit with 10 m cable
• AC version with capacitor switching device and free
cable end
• Three-phase current version with:
• free cable end
• CEE plug
• Installation and operation instructions
Freely configurable items
• Unit with cable length chosen by the customer
• Cable version with:
• free cable end
• plug
• float switch and free cable end
• float switch and plug
• Installation and operation instructions

4.9 Accessories (optionally available)

• Cable lengths up to 50 m in fixed increments of 10 m or
individual cable lengths on request
• Suspension unit
• Pump pedestal
• External leak electrode
• Level control
• Fixing accessories and chains
• Switching devices, relays and plugs
• Ceram coating
• Thermal motor monitor with PTC sensors
5 Installation
In order to prevent damage to the product or serious
injury during installation, the following points must be
observed:
• Installation work – assembly and installation of the
machine – may only be carried out by qualified per-
sons. The safety instructions must be followed at all
times.
• The machine must be inspected for transport damage
before carrying out any installation work.
5.1 General
For planning and operation of technical waste water
systems, attention is drawn to the pertinent local regu-
lations and directives for waste water technology (such
as the German Association for Water, Wastewater and
Waste).
Attention is drawn to pressure surges, in particular with
stationary installations in cases where water is pumped
with longer discharge pipes (especially with steady
ascents or cross country terrain).
Pressure surges can lead to destruction of the unit/sys-
tem and noisy operation resulting from valve knocking.
This can be avoided by taking appropriate measures
(e.g. non-return valves with adjustable closure time or
laying the discharge pipe in a special way).
After pumping water containing lime, clay or cement,
flush out the product with clean water in order to pre-
vent encrustation and subsequent breakdowns.
Installation and operating instructions Wilo-Rexa PRO...
If you are using level control, make sure that the mini-
mum water coverage is present. Air pockets must not
be allowed to enter the hydraulic housing or the pipe-
line system, and they must be removed with suitable
bleeding equipment and/or by inclining the machine
slightly (with a portable installation). Protect the prod-
uct from frost.
5.2 Types of installation
• Vertical stationary wet installation with suspension unit
• Vertical portable wet installation with pump pedestal
5.3 The operating area
The operating area must be clean, free of coarse solids,
dry, frost-free and, if necessary, decontaminated. It
must also be suitable for the respective product. When
working in shafts, a second person must be present for
safety reasons. If there is danger of poisonous or
asphyxiating gases forming, the necessary counter-
measures must be taken!
When installing in shafts, the size of the shaft and the
cool-down time of the motor must be determined by
the system planner, depending on the ambient condi-
tions prevailing during operation.
To keep dry motors sufficiently cooled when they
are not submerged, they must be flooded com-
pletely before being switched back on!
It must be ensured that hoisting gear can be fitted
without any trouble, since this is required for assembly
and removal of the product. It must be possible to
reach the product safely in its operating and storage
locations using the hoisting gear. The machine must be
positioned on a firm foundation. For transporting the
product, the load-carrying equipment must be secured
to the provided lifting eyelets.
Electric power cables must be laid out in such a way
that safe operation and trouble-free assembly/dis-
mantling are possible at all times. The product must
never be carried or dragged by the power supply cable.
When using switching devices, the corresponding pro-
tection class must be observed. Switching devices
must always be mounted in such a way that they are
protected from flooding.
When used in an explosive atmosphere, it must be
ensured that the product as well as all accessories are
approved for this purpose of use.
The structural components and foundations must be
of sufficient stability in order to allow the product to be
anchored securely and functionally. The operator or the
supplier is responsible for the provision of the founda-
tions and their suitability in terms of dimensions, sta-
bility and strength!
Never let the machine run dry. The water level must
never fall below the minimum. Therefore, we recom-
mend installing a level control system or a dry-run pro-
tection system where there are great variations in the
level.
Use guide and deflector plates for the pumped liquid
intake. If the water jet reaches the surface of the water,
air will be introduced into the pumped liquid. This will
lead to unfavorable current and pumping conditions for