10 V
2 V
0
V
0%
−8 V
28
The advantage of the reset function is that drift factors
can be compensated. A measurement can also only start
from a higher force level.
RESET
80%
Force removal
Fig. 7.3
Reset function
WARNING
After a reset, although the charge amplifier output is set
to zero, this does not mean that no force is present at the
sensor. This can cause danger for the operating person­
nel of the system in which the transducer is installed.
Implement appropriate safety measures to avoid over­
loads and to protect against resulting dangers.