<How to clean the filter>
1. Remove the air filter from the air intake grille.
2. Use a vacuum cleaner to remove light dust. If there is sticky
dust on the filter, wash the filter in lukewarm, soapy water,
rinse it in clean water, and dry it.
<How to remove the filter>
1. Take hold of the finger-hold on the air intake grille and
press it to the rear, and the grille will open downward.
2. Take hold of the finger-hold on the air filter, pull it toward
you.
Air intake grill
finger-hold
Screw
Air filter
Air filter finger-hold
* Take hold of the finger-hold on the air filter, pull it toward you.
CAUTION
● Certain metal edges and the condenser fins are sharp
and may cause injury if handled improperly; special care
should be taken when you clean these parts.
● Periodically check the outdoor unit to see if the air outlet
or air intake is clogged with dirt or soot.
● The internal coil and other components must also be
cleaned periodically. Consult your dealer or service
center.
Care: After a prolonged idle period
Check the indoor and outdoor unit air intakes and outlets for
blockage; if there is a blockage, remove it.
Care: Before a prolonged idle period
● Operate the fan for half a day to dry out the inside.
● Disconnect the power supply and also turn off the circuit
breaker.
● Clean the air filter and replace it in its original position.
● Outdoor unit internal components must be checked and
cleaned periodically. Contact your local dealer for this
service.
Air filter finger-hold
Air intake grill
Hook
Screw
Latch
■ Troubleshooting
If your air conditioner does not work properly, first check the
following points before requesting service. If it still does not
work properly, contact your dealer or a service center.
Trouble
Possible Cause
Air conditioner
1. Power failure.
does not run
at all
2. Leakage circuit breaker has
tripped.
3. Line voltage is too low.
4. Operation button is turned off.
5. The wired remote control unit
or heat pump is malfunctioning.
(The inspection mark
the letters E, F, H, L, P in
combination with numbers
appear the LCD of the wired
remote control unit.)
Compressor
1. Obstruction in front of
runs but soon
condenser coil
stops
Poor cooling
1. Dirty or clogged air filter.
(or heating)
performance
2. Heat source or many people
in room.
3. Doors and/or windows are
open.
4. Obstacle near air intake or air
discharge port.
5. Thermostat is set too high for
cooling
(or too low for heating).
6. (Defrosting system does not
work.)
■ Tips for Energy Saving
Avoid
● Do not block the air intake and outlet of the unit. If either
is obstructed, the unit will not work well, and may be
damaged.
● Do not let direct sunlight into the room. Use sunshades,
blinds or curtains. If the walls and ceiling of the room are
warmed by the sun, it will take longer to cool the room.
Do
● Always try to keep the air filter clean. (Refer to "Care and
Cleaning.") A clogged filter will impair the performance of the
unit.
● To prevent conditioned air from escaping, keep windows,
doors and any other openings closed.
NOT E
Should the power fail while the unit is running
If the power supply for this unit is temporarily cut off, the unit will
automatically resume operation once power is restored using
the same settings before the power was interrupted.
87
Remedy
1. After a power outage,
press ON/OFF
operation button on the
wired remote control
unit.
2. Contact service center.
3. Consult your electrician
or dealer.
4. Press the button again.
5. Consult your dealer.
and
1. Remove obstruction
1. Clean air filter to
improve the airflow.
2. Eliminate heat source if
possible.
3. Shut them to keep the
heat (or cold) out.
4. Remove it to ensure
good airflow.
5. Set the temperature
lower (or higher).
6. (Consult your dealer.)