9-10. Wiring the Ceiling Panel
(1) Open the cover of the electrical component box.
(2) Connect the 7P wiring connector (red) from the ceiling
panel to the connector in the unit electrical component box.
(Fig. 9-26)
(Direction that the unit faces has been changed to facilitate
explanation.)
Electrical component box cover
Screws
(3 locations)
* Pass the wiring connector through the clamp to fasten it in
place, as shown in the fi gure.
● If the connectors are not connected, the auto flap will not
operate. Be sure to connect them securely.
● Check that the wiring connector is not caught between the
electrical component box and the cover.
● Check that the wiring connector is not caught between the
unit and the ceiling panel.
9-11. How to Attach the Corner and Air Intake Grille
Attaching the corner cover and air-intake grille
A. Attaching the corner cover
(1) Check that the safety cord from the corner cover is
fastened to the ceiling panel pin.(Fig. 9-27).
Pin
Place the corner cover so that the 3 tabs fit into the
holes in the ceiling panel. Then fasten it in place with the
supplied screws.
(2) Use the supplied screws to attach the corner cover to the
ceiling panel.
B. Attaching the air-intake grille
● To install the air-intake grille, follow the steps for Removing
the grille in the reverse order. By rotating the air-intake
grille, it is possible to attach the grille onto the ceiling panel
from any of 4 directions. Coordinate the directions of the air-
intake grilles when installing multiple units, and change the
directions according to customer requests.
● When attaching the air-intake grille, be careful that the
flap lead wire does not become caught.
● Be sure to attach the safety cord to the ceiling panel
unit. This keeps the air intake grille from accidentally
dropping. (Fig. 9-28)
Ceiling panel wiring connector
Fig. 9-26
Fig. 9-27
Hole for ceiling
panel hook
Hook that prevents the
grille from dropping
● With this ceiling panel, the directions of the air-intake grille
lattices when installing multiple units, and the position of
the label showing the company name on the corner panel,
can be changed according to customer requests. However,
the optional wireless receiver kit can only be installed at the
refrigerant-tubing corner of the ceiling unit. (Fig. 9-29)
Locations of air-intake grille hinges
Refrigerant tube side
Optional wireless
receiver kit
* Only this area is
possible for installation.
Electrical component
box for power PCB
Electrical component box for control PCB
9-12. Checking After Installation
● Check that there are no gaps between the unit and the
ceiling panel, or between the ceiling panel and the ceiling
surface.
Gaps may cause water leakage and condensation.
● Check that the wiring is securely connected.
If it is not securely connected, the auto flap will not operate.
("P09" is displayed on the remote controller.) In addition,
water leakage and condensation may occur.
51
* The grille can be installed
with these hinges facing
in any of 4 directions.
Drain pipe
side
Can be installed rotated 90°
Fig. 9-28
Fig. 9-29