Structure and mode of operation

5
Structure and mode of operation
HBM torque transducer
12
Magnetic
The TIM-PN receives the measured data flow of the con­
nected torque transducer and provides it as scaled meas­
ured values to an PROFINET and an Ethernet interface
(UDP). Two digital filters that can be shut off are provided
for all signal paths. The low-pass filter is parameterized
via the Ethernet interface using an integrated web server.
When the TMC digital signal is connected, the internal
shunt signal of the connected torque transducer can be
activated either by a control bit of the PROFINET or the
web server. The shunt signal produces an output signal
corresponding to about 50% of the nominal (rated) mea­
suring range by means of a misalignment of the strain
gauge bridge in the transducer. It is used to monitor the
entire signal path and can be activated by the user for
this purpose.
The supply voltage can be forwarded without extra cir­
cuitry measures to supply the connected torque.