PROFINET data transmission and configuration
Error/error code
TIM_Parameter_Error
Measurement_Failure
Torque_Channel1_Failure
Torque_Channel2_Failure
84
Diagnosis mapping
Error code mapping and Profinet diagnosis are described
below.
The diagnostic messages are generated and realized as
a channel-specific diagnosis. They contain the following
information:
S Diagnosis source (where the diagnosis was localized)
S Diagnosis status (cause of the error or error expired/
disappeared)
S Channel-specific diagnosis (additional manufacturer-
specific errors)
S Diagnosis weighting
Diagnosis information generation
Measurement-specific errors are mapped to the relevant
modules. Device-specific errors are mapped to the DAP
(device access point or head-end).
Mapping
to module
Head
module
Head
module
Torque
module
Torque
module
A4341-2.0 HBM: public
Channel
Error text
error type
16
Paramter Error
Diagnosis: This is a TIM
Parameter Error
256
Measurement Failure
Diagnosis: This is a
Measurement Failure
257
Torque Channel Failuer 1
Diagnosis: This is a Torque
Channel Failure 1
258
Torque Failure Channel 2
Diagnosis: This is a Torque
Channel Failuer 2