TECHNICAL / PERFORMANCE DATA

E
C
NDO
ENTER
Model/Type
Manufacturer
Distributor
Dimension - Weight
Device protection class
Applied component type
Intermittent operation
Conformity
Ultrasonics
Maximum frequency
Maximum amplitude
Handpiece dimension & weight
Micromotor
Minimum speed
Maximum Torque
Handpiece dimension & weight
Power supply
Model
Imput voltage
Output
Ambient conditions
Operating temperature
Storage temperature
Atmospheric pressure
Altitude
Note
Not suitable for use in presence of flammable anesthetics or oxygen.
10.

DISPOSAL AND RECYCLING

As The E
C
™ falls under the category of electric/electronic equipment, the unit must be disposed of according to a spezialized
NDO
ENTER
procedure for collection, pick-up and recycling or destruction (especially on the European market, with reference to the Directive
2002/96/EEC of 27.01.2003).
As soon as the unit reaches the end of its life cycle, it is strongly recommended to contact the local dealer to obtain information on how to
proceed.
11.

WARRANTY

Important – please read this limited warranty carefully to understand your rights and obligations.
The manufacturer hereby certifies the correct construction of the product, use of top-quality materials, performance of all the required
testing, and product compliance to pertinent laws and regulations in force.
The product is covered by warranty for a period of 12 months (excluding tips) beginning on the date of delivery to the end user as attested
by the billing documents, containing the serial number of the unit, issued by the seller at the moment of purchase.
The user has the right to request assistance under warranty only during the warranty period and only on condition that he notifies the
manufacturer of the defect in writing within 2 months from the date the defect is noticed.
1. This warranty covers only replacement or repair of single components or pieces affected by manufacturing defects, excluding all
expenses for visits by technical personnel and packing expenses.
2. This warranty does not extend to damage or breakdowns attributable to incorrect maintenance, incorrect power supply, negligence,
and/or unskilled handling. The warranty does not cover trouble attributable to the user's negligent failure to perform ordinary
maintenance (see instruction manual).
3. This warranty does not provide for any compensation for direct or indirect damages of any kind to persons and/or things attributable
to the inefficient operation of the unit.
E
C
™ device
NDO
ENTER
By Dental - Via Vecchia Provinciale Lucchese, 49 F/G
51030 Serravalle Pistoiese - Italy
®
SATELEC
- 17 av. Gustave Eiffel - BP30216
33708 Mérignac Cedex - France
Control unit:255 x 100 x 195 mm - 1.4kg
Foot pedal: 173 x 43 x 177mm – 610g
Protection Class II
BF
5 min. Operation / 10 min. Pause
IEC. 60601-1, IEC 60.601-1-2, OC certified following CB scheme
28 khz
200 µm
Ø 21 x100 mm - 52 g
10.000 rpm with 1:1 Contra-angle
10 Ncm
Ø 20 x120 mm - 120 g
PowerBox - Medline EXM 80 - 5121
100 to 240 VAC
24 VDC - 2.9 Amps
+10 to +40°C at a maximum of
95% relative humidity without condensation
-20 to +70°C at a maximum of
95% relative humidity non condensing
500 to 1060 hpa
≤ 2000 meters (6500 feet)