Herunterladen Inhalt Inhalt Diese Seite drucken

Transferring The Project To The Unit; Loading A Project From The Unit; Project Administration With Memory Card; Locking The Unit - IMG STAGE LINE DSM-480LAN Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.8.6.4 Transferring the project to the unit

GB
A project can completely be transferred to the
memory of the DSM-480LAN. The previous
memory contents are overwritten. For free posi-
tions of the project list "-----" the contents of the
corresponding memory location in the unit
remain unchanged. Thus, it is possible to com-
plete or exchange only some configurations in
the unit.
To transfer the present project to the memory of
the DSM-480LAN:
1) In the window "Store Project" (
the button "Store Project to Device".
2) In the dialog window which opens "Store cur-
rent project to device, are you sure?" confirm
or cancel the procedure.
After successful transfer the message
"Project stored on the device" appears.

6.8.6.5 Loading a project from the unit

To load the complete configuration memory of
the DSM-480LAN as a project into the computer:
1) Click the button "Read Project from Device"
in the window "Store Project" (
2) In the dialog window opened "Read current
project from device - are you sure?" confirm
or cancel the procedure.
The progress of the transfer is shown in
the window "Store Project" at the bottom.
After loading, "Device project" can be found
under "Project Name" as a source of the project
loaded. The project can now e. g. be saved
on the computer (
chapter 6.8.6.2) or, as
described under "Compiling project" (
ter 6.8.6.1), be completed with memorized con-
figurations and then retransferred to the unit
(
chapter 6.8.6.4).

6.8.6.6 Project administration with memory card

The preceding chapters describe the storage
and loading of a project from the memory of the
unit to the PC. It is possible to administrate proj-
ects from the PC to the memory card in the same
way via the button "Store Project to Memory-
Card".
For the storage of configurations from a
memory card as a project, an individual folder
"CardProject" is created on the PC. However,
also other memory locations can be selected.

6.9 Locking the unit

As described in chapter 5.6.2, the unit may be
locked against accidental misadjustment. This is
also possible via the control programme:
Window "Store Project"
38
1) Click the following button.
The button now appears with a red
frame and the operation is locked.
After separating the connection (
6.11) the unit remains locked.
2) To unlock, click the button again.

6.10 Entering a password

To be able to lock the unit with a password or to
change the password of the unit, it is required to
fig. 24) click
enter the present password first.
Note: When delivered and after the reset of the
unit (
chapter 5.7), the following password
000000
applies:
To make an unauthorized access difficult, this
password should be changed in any case
(
chapter 6.10.2).
To enter the present password:
1) Click the following button.
The dialog window "Password –
Insert Password" (
The state of the unit is shown under
fig. 24).
the key:
"System Unlock" – unit not locked
"System Lock" – unit locked
chap-
Window "Insert Password"
2) Enter the present password into the field
"Insert Password" and confirm via the button
"OK" or cancel the procedure with "Exit".
After entering the correct password, the
window "Password" appears (
When entering a wrong password the
message "Password incorrect" appears.
After confirming the message the input may
be made once again.
Window "Password"

6.10.1 Locking the unit with a password

1) After entering the correct password in the
window "Password" (
with the left button or unlock it.
chapter
With the red lettering "Lock" and red button
the unit is locked. The lettering "Unlock" is red
when the unit is unlocked.
With the unit locked, no change of the adjust-
ments is possible. All upper buttons in the
main window cannot be operated except for
the button for password input and the button
for separating the connection. Even after

separating the connection (

the unit remains locked.
2) To confirm, click the button "Confirm".

6.10.2 Changing a password

1) After entering the present password in the
window "Password" (
ton "Config new password".
The window to enter the new password
opens.
fig. 25) opens.
2) Enter the new password into the field "Insert
New Password" and repeat it in the field
"Confirm New Password" to confirm. A pass-
word may consist of 6 characters as a maxi-
mum. Upper-case letters and lower-case let-
ters from the ASCII character set, numbers
and blanks may be entered.
If the input contains invalid characters, the
message "Value passwords incorrect" ap -
pears.
If the inputs in both fields are not in accor-
dance with each other, the message "Pass-
words donʼt match" appears.
After confirmation of a message the input
may be corrected.
3) For subsequent locking or unlocking, enter
the password again into the window opened
and confirm with "OK" or cancel the proce-
fig. 26).
dure with "Exit".
6.11 Separating the connection
To separate the connection between the PC
software and a DSM-480LAN, click the following
button.
In the dialog window which opens
"Do you want to disconnect this device,
are you sure?" confirm or cancel the
procedure.
Then the DSM-480LAN can directly be operated
again.
fig. 26), lock the unit
chapter 6.11)
fig. 26), click the but-

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis