When an invalid password is entered, the
following message appears:
Password Wrong!
In this case repeat the input from step 3).
When the input is correct, the following
message appears:
Password : Disable
(unit not locked)
6) Change the adjustment with the rotary knob
PM2 to
Password : Enable
(lock the unit with password)
and press the knob PM1/ ENTER to confirm.
The display shows the symbol
locked in this way. Now it is not possible any
more to change the adjustments or to mute
inputs or outputs. It depends on the preadjust-
ment "Show Parameter" if the adjustments for the
inputs or outputs are visible (

5.6.3.3 Unlocking the unit

To unlock the unit:
1) Press the knob UTILITY (5). The display
shows:
Enable Password:
[_
]
The flashing underscore marks the position
for inserting the first character.
2) Enter the password:
Change the flashing character with the rotary
knob PM2. Select the position of the next
character to be entered with the rotary knob
PM1.
3) To terminate the input, press the knob
ENTER.
When an invalid password is entered, the
following message appears:
Password Wrong!
In this case repeat the input from step 1).
When the input is correct, the following
message appears:
Password : Enable
4) Change the adjustment with the rotary knob
PM2 to
Password : Disable
and press the knob PM1/ ENTER to confirm.
5) To exit the submenu, press the knob ESC.

5.7 Reset of the unit

The unit can be reset to the factory settings.
Then all adjustments made by the user, includ-
ing the memorized configurations, are lost irre-
trievably. To maintain these configurations (Pro-
grams), they have to be saved on a memory card
(
chapter 5.5.4) or externally on a computer
(
chapter 6.8.6.5).
1) With the unit switched off, keep the knobs
ENTER (2), ESC (4) and UTILITY (5)
pressed at the same time and switch on the
unit with the POWER switch (11).
2) When the display shows the message
Doing Factory Reset
Please wait...........
release the knobs.
3) When after a few seconds the message
RESET MEMORY
Turn-off the device
appears, switch the unit off and on again.
All adjustments are now reset. The password
to lock the unit (
chapter 5.6.3) is again:
000000
6 Remote Operation
via a Computer
The DSM-480LAN may be remotely operated
via the supplied computer software. All adjust-
ments can be made like via the menu of the unit,
however, the presentation is much more clearly
*
arranged. The filter adjustments can also be
made graphically by mouse and the resulting fre-
quency responses and phases are shown as
curves. In addition, it is possible to change the
parameters of the Noise Gates, to copy adjust-
ments between the channels, to save configura-
tions on the computer and to administrate the
complete configuration memory as a project.
Ƈ
when a unit is

6.1 Installing the PC software

System requirements for the installation of the
supplied control programme are a PC with the
operating system Windows XP (SP2) or higher,
chapter 5.6.1).
a working memory of 256 MB as a minimum,
50 MB free hard disk memory and a USB inter-
face, Ethernet or RS-485 interface. The screen
resolution should be 1024 × 768 pixels as a min-
imum. For the installation of the PC software
start the installation programme SETUP.EXE on
the supplied CD and follow the instructions of the
installation programme.
Windows is a registered trademark of the Microsoft Corporation in the USA and
other countries.

6.1.1 Installing the USB driver

A special driver is required for connection via the
USB interface. This driver is available on the
supplied CD. For automatic installation of the
driver call the file USB[...]SETUP.EXE. The
driver simulates a serial interface for the operat-
ing software.

6.2 Selecting the interface

To switch over between the RS-485 interface,
the Ethernet interface and the USB connection:
1) To call the menu, press the knob UTILITY (5).
*
System Utilities
2) Use the rotary knob PM1/ ENTER (2) to select
the menu item
and press the knob to confirm.
Setup
3) Press the knob ENTER again.
4) Use the rotary knob PM2 (4) to define if the
USB interface (
interface (
net interface (
used. The present adjustment is marked
5) Confirm the selection by pressing the knob
ENTER or cancel the procedure by pressing
the knob ESC (4).
6) When the RS-485 interface or the Ethernet
interface has been selected, additionally
define the unit number to distinguish several
units at the data bus:
Turn the rotary knob PM1 clockwise so that
the unit number is shown, e. g.:
Remote ID Num = 01
When controlled via the Ethernet interface,
the unit number is defined by the last two
digits of the IP address of the unit, e. g.:
IP ADDR = 192.168.0.101*
Use the rotary knob PM2 to adjust the
desired number (
knob ENTER to confirm.
7) To exit the adjusting menu, press the knob
ESC three times.
is shown.
Interface Utilities
Interface
is shown.
Source : USB
), the RS-485
Source : RS485
) or the Ether-
Source : TCP/IP
) is to be
*
01
32
to
) and press the

6.3 Starting the PC software

1) Start the control programme
DSM-480LAN Vx.x.EXE on the PC.
2) Select the desired interface ("USB", "RS485"
or "TCP/ IP") in the dialog window "Select"
under "Communication Port".
3) If "USB" is selected (
face which the driver simulates for the soft-
ware has to be selected under "COM Select".
It is possible to find the present COM inter-
face in the adjustments of the operating sys-
tem under ± Control Panel ± System Proper-
ties (Hardware) ± Device Manager ± Ports
(COM and LPT). It reads e. g.
If conflicts occur with other units, the number
of the COM interface can be changed here (via
± Properties ± Port Settings ± Advanced ...).
Window „Select Communication Port" – USB
4) When "RS485" or "TCP/ IP" is selected
(
fig. 9), select under "Connection" if only
one DSM-480LAN or several units are to be
controlled:
1 DSM-480LAN ©"with one device"
2 – 32 DSM-480LAN ©"with several devices"
If "with one device" has been selected, in the
field "ID Select" or "IP Address" select the
number entered in the respective unit
(
chapter 6.2). If "with several devices" has
been selected, the program will automatically
find the unit numbers with the following step.
*
.
Window „Select Communication Port" – TCP/ IP
5) Confirm the selection by clicking the button
"Connect" (or exit the programme by clicking
"Exit").
GB
fig. 8), the serial inter-
31