Code
Function
265 +(Address) *100
HEAT2
266 +(Address) *100
Discharge temperature 1 °C
267 +(Address) *100
Suction temperature
268 +(Address) *100
Temperature T3A
269 +(Address) *100
Temperature Tz
270 +(Address) *100
Temperature T5
271 +(Address) *100
P pressure
272 +(Address) *100
Error / Protection
273 +(Address) *100
Last error / Protection See error codes
274 +(Address) *100
Software version
275 +(Address) *100
Discharge
temperature 2
276 +(Address) *100
Temperature T3B
277 +(Address) *100
Temperature T6A
279 +(Address) *100
SV6 status
280 +(Address) *100
Compressor 2
absorption
281 +(Address) *100
Unit capacity
282 +(Address) *100
not used
Faults and errors
In the BMS reading register 272, 273 displays one of the following errors
codes in decimal format, only considering the BYTE LOW. Only consider
the last two alphanumeric digits of the code.
Faults code
E0
Fault number (dec)
1
Fault code
EF
Fault number (dec)
16
Fault code
PA
Fault number (dec)
31
Fault code
H5
Fault number (dec)
46
Fault code
F0
Fault number (dec)
61
Fault code
FF
Fault number (dec)
76
Fault code
CA
Fault number (dec)
91
Fault code
L5
Fault number (dec)
106
Fault code
d0
Fault number (dec)
121
Fault code
dF
Fault number (dec)
136
Table 60
CS3000 AWP – 6721852570 (2022/11)
Description
0 = Off
1 = On
1 °C
1 °C
1 °C
1 °C
10 kPa
See error codes
table
table
HMI
1 °C
1 °C
1 °C
0 = Off
1 = On
1A
Kw
E1
E2
E3
E4
2
3
4
5
EH
EL
EP
EU
17
18
19
20
PB
PC
PD
PE
32
33
34
35
H6
H7
H8
H9
47
48
49
50
F1
F2
F3
F4
62
63
64
65
FH
FL
FP
FU
77
78
79
80
CB
CC
CD
CE
92
93
94
95
L6
L7
L8
L9
107
108
109
110
d1
d2
d3
d4
122
123
124
125
dH
dL
dP
dU
137
138
139
140
Code
283 +(Address) *100
284 +(Address) *100
286 +(Address) *100
287 +(Address) *100
289 +(Address) *100
290 +(Address) *100
291 +(Address) *100
292 +(Address) *100
293 +(Address) *100
Table 59
E5
E6
E7
E8
6
7
8
9
P0
P1
P2
P3
21
22
23
24
PF
PH
PL
PP
36
37
38
39
HA
HB
HC
HD
51
52
53
54
F5
F6
F7
F8
66
67
68
69
C0
C1
C2
C3
81
82
83
84
CF
CH
CL
CP
96
97
98
99
LA
LB
LC
LD
111
112
113
114
d5
d6
d7
d8
126
127
128
129
Function
Description
Anti-freezing electric
0 = Off
heater
1 = On
Remote control
0 = Off
1 = On
Pump control type
1 = multiple pumps
0 = single pump
Unit type
1
Safety temperature
1 °C
Minimum safety
10 kPa
pressure
Taf1 IN-LET BPHE
1 °C
TEMP
Board software version –
EEPROM version
E9
EA
Eb
EC
10
11
12
13
P4
P5
P6
P7
25
26
27
28
PU
H0
H1
H2
40
41
42
43
HE
HF
HH
HL
55
56
57
58
F9
FA
FB
FC
70
71
72
73
C4
C5
C6
C7
85
86
87
88
CU
L0
L1
L2
100
101
102
103
LE
LF
LH
LL
115
116
117
118
d9
dA
dB
dC
130
131
132
133
Modbus
Ed
EE
14
15
P8
P9
29
30
H3
H4
44
45
HP
HU
59
60
FD
FE
74
75
C8
C9
89
90
L3
L4
104
105
LP
LU
119
120
dD
dE
134
135
81

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis