86 | Technical specifications
BPT-C 200, 300, 350 | Operating manual
DC input data (solar generator)
Min. (V
) ... max. (V
) DC input
dcmin
dcmax
voltage [V
]
DC
Start-up input voltage (V
) [V
dcstart
Rated input voltage (V
) [V
]
dc,r
DC
Min. (V
) ... max. (V
mppmin
mppmax
voltage [V
]
DC
Maximum input current (I
) [A
dcmax
Maximum short-circuit current of the solar
generator (I
) [A]
sc.dcmax
Maximum feedback current [A]
Grid injection from [W]
Fuse per input (device-internal, thermal),
configurable [A]
Efficiency
Maximum efficiency
European efficiency
Californian efficiency
Efficiency: At DC and AC rated voltage and cos φ = 1 without involvement of auxiliary power
supply. Depending on the revision status of the central inverter in question, the values may
differ from those specified here.
Due to developments in production, actual performance figures may differ
slightly from the technical specifications listed here.

10.3 Information on selection of country

Country-specific parameter sets in line with the grid connection directives
are saved in the display. Each country-specific parameter set contains the
upper and lower thresholds of the grid voltage and grid frequency. Select
the country-specific parameter set during commissioning (Display: Setting
the grid standard and parameters, p. 68).
Selecting the country sets a country-specific set of parameters. The
manufacturer has defined country-specific parameter sets in line with
country-specific standards.
The central inverter only works if a set of parameters is set. If you want to
use the device in a country that is not listed in the display: Contact Bosch
Power Tec Service (see contact details on the back of the manual).
On the day of commissioning, you have the option to select another country
with the corresponding parameter set. To do this, start the central inverter
by switching off it briefly and then switching it back on again.
If you have set the incorrect country during first commissioning: Switch off
the central inverter and then switch it back on. Then enter the correct
country.
Level of performance
200 kVA
300 kVA
530 ... 1000
530 ... 1000
]
580
580
DC
540
540
) MPP
530 ... 800
530 ... 800
]
400
590
DC
800
800
250
250
1800
1800
175 ... 250
175 ... 250
Level of performance
200 kVA
300 kVA
98.7%
98.7%
98.3%
98.5%
98.6%
98.6%
English
350 kVA
580 ... 1000
640
600
580 ... 800
650
800
250
1800
175 ... 250
350 kVA
98.7%
98.5%
98.6%
Bosch Power Tec GmbH