Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch Rexroth PSI 6 C Serie Typspezifische Anleitung Seite 62

Schweißsteuerung mit mittelfrequenz-umrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

62/91
Bosch Rexroth AG
Input/Output array
Bits
Outputs (status word)
5.10
Contouring error
5.11
Not used
5.12
Failure servogun (group signal)
5.13
Failure transformer temperature
5.14
Failure motor temperature
5.15
Timer fault
6.00
Weld Complete
6.01
Tip dress warning electrode
6.02
Acknowledge tip dress detected
6.03
Start tip dress request electrode
6.04
Tip dress sum
6.05
Not used
6.06
Electrode warning
6.07
Weld on (with weld current)
6.08
Calibration finished
6.09
Calibration ok
6.10
Calibration not ok
6.11
Reserved
6.12
Reserved
6.13
Reserved
6.14
Reserved
6.15
Reserved
7.00
End of stepper
7.01
Timer ready
7.02
With monitoring
7.03
Weld OK
7.04
Weld not OK
7.05
Warning limit consecutively violated
7.06
Not used
7.07
Linked to discrete input bit 1 (negated)
7.08
Mains voltage low or off
7.09
Overcurrent on primary side
7.10
Current sensor error
7.11
Voltage sensor error
7.12
Not used [reserved for overcurrent 24V DC]
7.13
Inverter overtemperature
7.14
Spot selection error