Timer diagrams

Auto calibration
9
Timer diagrams
Enable positioning
Start calibration
Gun is referenced
Calibration ready
Calibration ok
Calibration not ok
Fig. 5:
Auto calibration ok
Enable positioning
Start calibration
Gun is referenced
Calibration ready
Calibration ok
Calibration not ok
Combined fault
Fig. 6:
Auto calibration not ok
Auto calibration
Break close
(Energy saving mode on)
With Energy saving mode regulation enable
Break closed
(Energy saving mode on)
Ready for gun change
(Regulation enable off)
Automatic is on
Energy saving mode
Fig. 7:
Energy saving mode
While calibration the gun close several times with force.
Before starting calibration the gun has to be referenced!
While calibration the gun close several times with force.
Before starting calibration the gun has to be referenced!
will be switched off and the break closed.
R911174319 | PSI6xCx.789xx
1)
1) Calibration is not ok, if
-gun not ready or
-calibration quality > 20 or
-force deviation > 150N
(Limits adjustable)