R911174319 | PSI6xCx.789xx
• "Maintenance interval" = 0 -> welding spots will not be counted
• If the counter reaches the value „Warning maintenance", then will be displayed
a status message and the output "Prewarning gun " set.
• If the counter reaches the value „Maintenance interval", then will be displayed a
status message and set the output "Warning lubrication"
The maintenance counter will be reset with writing of the counter to 0.
7.1.5

Component counter

Each electrode are assigend 9 component counter. For each counter can be
defined a warning limit and a Max. limit. The names of the counter can be defined
via the BOS6000 configuration.
If one of the counter reach the warning or max. limit, then will be displayed a
corresponding status message.
In BOS6000 -> Programming -> Counter can be checked in this case, which of
the counter is affected.
Notice: For programming of the counter refer to Rexroth BOS6000 Online Help
„Programming: Counter".
7.1.6

Function test without component

If the input "Function test without component" is set,
• All times of a selected program are took over
• Mode KSR is set for this program
• A programmable Current value is set for all weld times
• A programmable force value is set
• Stepper is not active
The control runs in "ghost mode".
After the sequence, only output "Weld complete" will be set. "Weld OK"
respectively "Weld not OK" will not be set.
If the weld timer via the user interface or a hand held programming terminal is set
to "manual mode" or to "calibration mode", then the input "function test without
component"will be ignored.
The output „Feedback function test without component" will be set within a
welding sequence, if this runs as „Function test without component".
Outside of a welding sequence mirror the output „Feedback function test without
component" the input „Function test without component".
7.1.7

Welding without force

If the input „No force, no weld" is 1 during the start of a welding sequence, the
gun won´t be closed. The welding sequence is run without welding current.
The output „Force on" is only 1 if the input „No force, no weld" is 0.
The output „Force on" is set to 0 if the input „No force, no weld" is 1.