9.8.3
Splitting balance weights (SPLIT program)
Fig. 52:
Non-standard programs
i
When using the non-standard programs (ALU2,
ALU3, Pax2), the external balance weight can be
attached so it is concealed behind the spokes.
i
The "SPLIT program" is opened after measurement
if the balance weights have to be attached at a
certain position (e.g. behind the spokes). We
recommend attachment using Easyfix®.
1. Select the SPLIT program and the number of spokes.
2. Move the required position (e.g. a spoke) to the 12
o'clock position
3. Confirm by pressing <OK> .
« The split weights and positions are indicated.
4. Fasten the balance weights with the aid of the
electronic rim-distance gauge Easyfix® .
i
For details on fastening the adhesive balance
weights with the electronic rim-distance gauge, see
section "Attaching adhesive balance weights".
OMCN spa
Program structure | ROLL R8 (P-LOCK) | 97
9.9
Attaching clip-on balance weights
i
Use the balance weight pliers to locate the clip-on
balance weights.
Fig. 53:
Balance weight pliers
1 Tip for removing the clip-on balance weight
2 Hammer for fastening the weight to the rim
3 Shears for cutting the adhesive balance weights
4 Groove for pressing in the clip-on balance weight
5 Blade for scraping the adhesive balance weights
1. Once the exact position for the balance weight has
been found, put the clip-on balance weight on the
edge of the rim.
2. Fasten the clip-on balance weight to the rim with the
hammer of the balance weight pliers (2).
Fig. 54:
Attaching a clip-on balance weight
i
Use the tip (1) of the balance weight pliers to
remove the clip-on balance weight.
en
|
1 695 600 696