Error
Causes
ERROR 17
Weight outside setting range (weight required for
balancing is more than 250 g).
ERROR 18
Rim data not entered.
ERROR 19
Input signal of right measurement sensor lower than that
of left sensor.
+ Pedal pressed during measurement.
ERROR 20
+ Irregular rotational speed of motor.
+ Wheel speed below minimum value.
ERROR 21
The circuit board has detected an excessively high wheel
speed with the wheel-guard hood open (shaft rotating at
high speed without the ROLL R8 (P-LOCK) having been
started): power supply unit deactivated.
ERROR 22
Irregular measurement sensor signals.
ERROR 27
Incorrect measurement of wheel width
ERROR 29
Rim-distance gauge/sonar not in rest position.
ERROR 30
Electronic rim-distance gauge/measurement sensor was
deactivated.
ERROR 31
Pedal being pressed. Deactivation takes place.
ERROR 32
Pedal has been pressed.
ERROR 33
Incorrect operating system!
ERROR 34
Software error
ERROR 37
Printer is not connected.
ERROR 38
Text idiom missing.
ERROR 39
Incorrect version of WINCE firmware for chosen
language.
ERROR 40
Emergency stop.
ERROR 42
Pneumatic flange is open
ERROR 43
Time for obtaining the wheel width data by the
measurement sensor expired.
ERROR 44
Wheel cover not opened completely
OMCN spa
Faults | ROLL R8 (P-LOCK) | 103
Remedy
Check whether the wheel is correctly attached to the
flange.
Enter rim data before performing measurement.
Inform customer service.
+ Do not press pedal while motor is in operation:
+ Make sure the ROLL R8 (P-LOCK) is not subjected to
any impact during measurement.
+ Check the voltage (probably too low).
+ Switch off the ROLL R8 (P-LOCK).
+ Lower wheel-guard cover, switch the
ROLL R8 (P-LOCK) on again without moving the
wheel.
Inform customer service.
Inform customer service.
Repeat measurement.
Move rim-distance gauge/sonar to rest position.
Inform customer service.
Avoid pressing the pedal during the measuring cycle.
Avoid pressing the pedal during the measuring cycle.
Inform customer service.
Inform customer service.
+ Check whether the printer is switched on.
+ Check that the cable is connected to the graphics
card.
+ Check that the printer has no malfunctions during
normal operation.
Inform customer service.
The chosen language will be replaced with English.
Repeat the measuring cycle.
Close the pneumatic flange by pressing the pedal.
Repeat measurement.
Open wheel cover completely.