Herunterladen Inhalt Inhalt Diese Seite drucken

Automatic Selection Of Balancing Program - OMCN ROLL R8 SONAR P-LOCK Betriebsanleitung

Radauswuchtmaschine
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
90 | ROLL R8 (P-LOCK) | Program structure
9.4
Automatic selection of balancing
program
ROLL R8 (P-LOCK) automatically detects the 3
balancing programs Standard, ALU2 and ALU3 when
using the electronic rim-distance gauge. One of the
3 programs is selected on the basis of the number of
points acquired using the electronic rim-distance gauge:
Number of
Automatically selected program
measurement points
1
Standard
1
2
ALU3
1
3
ALU2/PAX2
1
Tab. 4:
Number of measurement points - automatically selected
program
Open the "Balancing" menu on the Start page by
pressing <OK> .
!
To prevent damage to the electronic rim-distance
gauge, it must always be moved to the rest position
by hand.
Fig. 40:
Moving the electronic rim-distance gauge manually to the
rest position
|
1 695 600 696
2016-09-30
2
3
2
i
With the balancing programs ALU2 and ALU3, all
measurement points needed are determined by the
electronic rim-distance gauge.
1. Position the electronic rim-distance gauge that
measures the distance and diameter of the rim
on the rim bead and hold in this position for one
second.
Fig. 41:
Determining the 1st measuring point and 1st balancing
plane for Standard and ALU3
« An audible signal sounds to confirm storage of
the position.
i
If the electronic rim-distance gauge is put back in
the rest position, the Standard balancing program
is selected automatically. Continue with step 2 for
ALU2 and ALU3.
OMCN spa

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Roll r8 monitor

Inhaltsverzeichnis