Herunterladen Diese Seite drucken

Dometic NDS POWER SERVICE PSB Montage- Und Bedienungsanleitung Seite 6

Gleichstrom-ladegerät

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
EN   PSB12-40-24-12-80
Follow the instructions of the battery manufacturer and those of the manufacturer of the system or
vehicle in which the battery is used.
If the battery has to be removed, first disconnect the ground connection. Disconnect all connections
and all consumers from the battery before removing it.
Only store fully charged batteries. Recharge stored batteries regularly.
Do not carry the battery by its terminals.
Safety precautions when handling lithium batteries
CAUTION! Risk of injury
Only use batteries with integrated battery management system and cell balancing.
NOTICE! Damage hazard
Only install the battery in environments with an ambient temperature of at least 0 °C .
Avoid deep discharge of the batteries.
Safety precautions when handling lead acid batteries
CAUTION! Health hazard
The water-acid liquid inside the battery can evaporate and cause an acidic odor. Use the battery only in a
well-ventilated area.
NOTICE! Damage hazard
The battery is not sealed. Do not turn the battery on its side or upside down. Place the battery on a
horizontal surface.
Check the acid level for open lead acid batteries regularly.
Immediately recharge deeply discharged lead acid batteries to avoid sulfation.
4 Scope of delivery
• DC-DC Charger
• Fuse, 80 A
• Fuse, 110 A
5 Accessories
Component
Temperature sensor TS002
Display
DTB01
TD283
6 Intended use
The battery charger is intended to monitor and charge house batteries in recreational vehicles by the alternator while
driving.
6
Ref. no.
9620008145
9620008325
9620013272

Werbung