EN PSB12-40-24-12-80
LED
Description
Orange
Battery deep discharged.
Voltage lower than 12 V or 24 V in charging phase 1 and 2 (depending on the model).
Green
Battery completely charged, maintenance mode.
Table 3: Terminal block
PIN
Designation
1
D+ terminal
2
Sense +
3
Sense -
4
Temp 1
5
Temp 2
6
–
7
–
Battery charging function
A main charging cycle of the house battery is initiated in the following situations:
• Aer a standstill of the alternator
• Aer falling below the reset voltage
10
1
2
3
4
Description
Input for D+ signal of the alternator or ignition lock signal (terminal 15)
Signal (+) output voltage
Signal (-) output voltage
Connection for temperature sensor (optional)
Not used
Remote charging status signal
5
6
7