Herunterladen Inhalt Inhalt Diese Seite drucken

MADRIX PLEXUS Handbuch Seite 103

Vorschau ausblenden Andere Handbücher für PLEXUS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

'Valid Thru'
defines together with 'Valid From' a time interval, in which the event will be
triggered. 'Valid Thru' sets the end point.
'Cycle
defines a time period for the 'Type' 'Cycle' in HH:MM:SS (Hours:Minutes:Seconds).
Interval'
Note: If you are setting up several different Timers that should trigger at the same times but at
different dates (daily, weekly, once on a specific date, etc.), then more specific Timers should be
set up after general Timers lower in the list (daily should be higher than weekly; weekly should be
higher than once, etc.)
Extension Ports:
The tab 'Extension Ports' allows you to configure the individual pins of the extension port.
First, please select one PLEXUS Configuration you wish to edit.
Restores all settings of the currently selected Ports to their default values. This will
discard any changes you have made.
Please edit the following columns according to your requirements.
(Perform a double-click to change their values. Use Enter to apply your changes. Use Escape to
cancel.)
'Type'
defines the character for each Port. On the one hand, 'Ports 1 - 6' can be either
'Digital Input', 'Digital Output' or 'Analog Input'. On the other hand, 'Ports 7 -
10' are only digital ports and can be switched from 'Digital Input' to 'Digital
Output' and vice versa.