Switch-on sequence
8.
Set the minimum output frequency
(C0010)
Lenze setting: 0.00 Hz
9.
Set the maximum output frequency
(C0011)
Lenze setting: 50.00 Hz
10. Set the acceleration time T
Lenze setting: 5.00 s
Lenze setting: 5.00 s
11. Set the deceleration time T
Lenze setting: 5.00 s
Lenze setting: 5.00 s
12. Set the V/f-rated frequency (C0015)
Lenze setting: 50.00 Hz
13. Set the V
min
Lenze settings: Depending on the
controller type
14. If you want to change the settings,
please go to the menu
After parameter setting:
15. Setpoint selection
16. Enable the controller.
17. The drive should now be running at
e.g. 30 Hz
L
(C0012)
ir
(C0013)
if
boost (C0016)
A A A A L L L L L L L L
. ( ¶ 26)
EDK82EV222 DE/EN/FR 6.0
Linear V/f-characteristic control
[f]
C0011
C0010
0 %
U
out
100%
U
min
0
0
C0015
E.g. JOG frequencies (C0037,
C0038, C0039), deceleration time
for quick stop (QSP) (C0105) or
motor temperature monitoring
(C0119)
E.g. via potentiometer at terminals
7, 8, 9
d
c
b
e
a
Œ
j g f k i h PS
‚ m n o
p
q
r
Hi
Lo
Commissioning
Note
100 %
T
= t
ir
t
= acceleration time wanted
ir
T
= t
if
t
= deceleration time wanted
if
The Lenze setting is
suitable for all common
applications
f
The most important codes
listed in the menu
explained in the code table.
( ¶ 39)
Terminal X3/28 = HIGH
If the drive does not start,
u
press
Hz
7
C0011
ir
f 2 − f 1
C0011
if
f 2 − f 1
A A A A L L L L L L L L
are
in addition.
33

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis