Commissioning
7
Code table (excerpt)
Code
No.
Name
C0010
Minimum output
frequency
U U U U S S S S E E E E r r r r
C0011
Maximum output
frequency
U U U U S S S S E E E E r r r r
C0012
Acceleration time
main setpoint
U U U U S S S S E E E E r r r r
C0013
Deceleration time
main setpoint
U U U U S S S S E E E E r r r r
C0014
Control mode
v
v
C0015
V/f rated
frequency
U U U U S S S S E E E E r r r r
46
Possible settings
Lenze
Choice
0.00
0.00
14.5 Hz
à
50.00 7.50
87 Hz
à
5.00
0.00
5.00
0.00
-2-
V/f-characteristic control V ~ f
-2-
-3-
V/f-characteristic control V ~ f
-4-
Vector control
-5-
Sensorless torque control with
speed limitation
Torque setpoint via C0412/6
Speed limitation via setpoint 1
(NSET1-N1), if C0412/1 is assigned,
if not via max. frequency (C0011)
50.00 7.50
EDK82EV222 DE/EN/FR 6.0
{Hz}
650.00 Application I/O supports
{Hz}
650.00
{s}
1300.00 Reference: frequency
{s}
1300.00 Reference: frequency
2
{Hz}
960.00 Setting applies to all
IMPORTANT
650 Hz as of version
E82AF ... XXVB21
C0010 is not effective
with bipolar setpoint
selection
(-10 V ... + 10 V)
C0010 has no effect on
C0010 has no effect on
AIN2
Speed setting range
à
1 : 6 for Lenze
geared motors:
Setting absolutely
required for operation
with Lenze geared
motors.
change 0 Hz ... C0011
change C0011 ... 0 Hz
Linear characteristic with
constant V
boost
min
Square-law
characteristic with
constant V
boost
min
For initial selection with
For initial selection with
C0148, identify the
motor parameters.
Otherwise,
commissioning is not
possible.
mains voltages permitted