Fault detection and elimination
?
Faulty drive behaviour
Fault
Cause
Current
Current
Setting of C0016 too high
consumption of
consumption of
Setting of C0015 too low
motor too high
C0084, C0087, C0088, C0089, C0090, C0091
and/or C0092 are not adapted to the motor data
Motor rotates,
With the function
setpoints are "0"
has been selected.
Motor parameter
Motor too small compared with rated power
identification
identification
stops with error
DC brake active via terminal
LP1
Unacceptable
various
drive response
with vector
control
58
j
of the keypad a setpoint
EDK82EV222 DE/EN/FR 6.0
Remedy
Correct setting
Correct setting
Manual adaptation or identification of
motor parameters (C0148)
Set the setpoint to "0" by C0140 = 0
Vector control optimisation ( ¶ 38)