10.2

Information and warning symbols

Wrong engine type selected
Trigger clamp-on pickup or diesel adapter error
- Pickup or adapter properly connected?
Primary connecting cable (terminals 1/15) error
- cable with breaks?
(on vehicles with multi-circuit system, evtl. an
ignition circuit is disturbed or not connected)
TDC sensor signal error.
Stroboscope error
- defective cable?
- connection ok?
Oil temperature sensor error
- connection ok?
Adjustment to zero not possible
by resistance measurement and/or current
measurement
No current measurement possible
Current clamp-on pickup or current measuring
shunt defective, not connected?
- defective cable?
No voltage measurement possible
Multi measuring cable defective?
- connection ok?
No resistance measurement possible
Multi measuring cable defective?
- connection ok?
No injection time measurement possible
Multi measuring cable defective?
- connection ok?
Permanent short circuit (suppression of the ignition)
only possible when the engine does not run.
Engine OFF. No permanent short circuit pos-sible
if diesel adapter is plugged in.
Reading of the „stored values" not possible
because no measured values have been stored or
no oscillograms stored in picture memory.
94
Change-over into the oscilloscope operating not
possible.
Storage (memorization) of oscillograms are not
possible because entry signal for triggering are
not present.
Exhaust gas tester not connected or not ready for
measurement.
Start the engine (actuate the starter)
Compression measurement is not possible (e.g.:
not all sensors connected, speed not in starter
range or asymmetric engine with single-spark
ignition coil selected).
Conduct test for leaks.