Plug-in socket 9: TDC sensor e.g.: for VW/Audi (1 687 224 600)
with connecting cable 1 684 463 198. The TDC sensor and the
connecting cable are special accessories and must be ordered
separately.
Plug-in socket 10: Connection for record printer (RS 232
interface) with connecting cable 1 684 465 266 for MOT 250
(4.5 m long) or connecting cable 1 684 465 283 for MOT 240 and
MOT 251 (1.5 m long). The record printer and the connecting
cables are special accessories and must be ordered separately.
Plug-in socket 11: Connection for exhaust gas tester
ETT 8.21 to 8.41 or ETT 8.5x/8.6x/8.7x (RS 232 interface) with
connecting cable 1 684 465 264 for MOT 240 (4.5 m long) or
connecting cable 1 684 465 233 for MOT 240 and MOT 251
(2.3 m long). The exhaust gas tester and the connecting cables
are special accessories and must be ordered separately. For the
German exhaust gas analysis (AU) it is also possible to connect
an smokemeter (RTT 100/110) via an interface switch.
Plug-in socket 12: (only for Germany) Connection for ASCII
keyboard 1 687 022 294 with connecting cable 67 cm long or
ASCII keyboard 1 687 022 295 with connecting cable 4.5 m long
for the German exhaust gas analysis (AU) (with RS 232 interface
in each case). The keyboards are special accessories and must
be ordered separately. As alternative, it is also possible to
connect the data terminal (DTL) 1 687 022 224 with connecting
cable 1 684 465 320 (no display appears on the data terminal
monitor in this case).
Plug-in socket 13: Program module PPG 240/250
66
Plug-in socket 14:
For Motortesters 250/251 (CRT):
Internal interconnecting cable for control and display unit (video
signal and keypad)/(power supply for measuring unit).
For Motortester MOT 240 (liquid-crystal display):
Simultaneous output for second display, e.g.:
- Standard VGA monitor (BA signal, 0.7 V video, 0.3 V synch.).
The interconnecting cable from the MOT 240 to the monitor
must be made in-house. For further information, contact your
local Bosch dealer.
- Monitor or control and display unit of Motortester MOT 250
(1 687 023 102) with mains connecting cable (1 684 461 119)
and interconnecting cable 4.5 m long (1 684 465 265). The
MOT 240 can also be remotely controlled with the control and
display unit of the MOT 250. All components are special
accessories and must be ordered separately.
Plug-in socket 15:
For Motortesters 250/251 (CRT):
Internal interconnecting cable for control and display unit (voltage
supply for measuring unit).
For Motortester MOT 240 (liquid-crystal display):
Connection for line adapter/power supply unit 1 687 022 296
(100 to 240 V / 50 to 60 Hz) or for connecting cable
1 684 463 264 for external power supply (battery, etc.). All
components are special accessories and must be ordered
separately.