ENGLISH
Faults
The pilot light goes out.
The pilot light ignites but
the burner remains off .
The fl ame is yellow.
The appliance does not
heat up.
The control panel does
not come on.
Alarm
E00
Safety thermostat failure.
Start the cooking well
E01
probe (well sx).
Start the cooking well
E.01
probe (well sx).
Start the cooking well
E02
probe (well dx).
Start the cooking well
E.02
probe (well dx).
28
Causes
The thermocouple has not
warmed up enough.
Burner dirty, heat exchange
pipes clogged, condensation
drips.
Contactor not receiving
power or faulty.
Electronic circuit board not
receiving electrical power.
TABLE OF ALARM INDICATIONS
Causes
cycles can be carried out. Reset the safety thermostat
Make more attempts to light the
Check the condition of the ther-
mostat and activate any ignition
servizio assistenza.
Check the condition of the ther-
mostat and activate any ignition
Check or replace the contactor coil.
The appliance's functions are disabled so no cooking
(see page 24), if the problem persists, call the after-
sales service.
The appliance's functions are disabled so no cooking
cycles can be carried out.
NOTE: Contact the after-sales.
The appliance's functions are disabled so no cooking
cycles can be carried out.
NOTE: Contact the after-sales.
The appliance's functions are disabled so no cooking
cycles can be carried out.
NOTE: Contact the after-sales.
The appliance's functions are disabled so no cooking
cycles can be carried out.
NOTE: Contact the after-sales.
Remedies
fl ame.
enabling device.
NOTE:
Contattare il
enabling device.
Check or swap the phase wire
connections.
Remedies
3019703_ut_GB
FAULT