ENGLISH
To carry out this operation, proceed as follows.
IMPORTANT: Before proceeding, let
the oil cool down to the environment tem-
perature or allow for the appliance to cool
for about 15 min., so that the oil reaches a
temperature between 50÷120 and use suit-
able PPE to prevent scalds.
Open the hatch (A).
1)
Fit the extension (B) onto the tap (C).
2)
Place the container (D) and the fi lter (E) both
3)
available as optionals, underneath the exten-
sion (B).
Turn on the tap (C) to empty the well.
4)
Turn off the tap (C) on completion of the op-
5)
eration.
Close the hatch (A).
6)
WARNING: Do not dump oil in the en-
vironment; dispose of it in accordance with
the laws in force in the country of use.
If the safety thermostat is tripped, the appli-
ance has to be restored to the initial working
conditions as follows.
Allow the oil to cool to 30÷40°C.
1)
Open the hatch (A).
2)
Press the button (B) of the safety thermostat
3)
tripped to restore the gas supply.
NOTE: To identify the thermostat that
has tripped, check which burner has turned
off and press the relevant button.
Close the hatch (A).
4)
24
FILTERING OIL
RESETTING THE APPLIANCE
USE AND OPERATION
3019703_ut_GB