16. Troubleshooting
In the interests of operational safety, always switch off the saw and remove the mains plug before carrying out
maintenance work.
Problem
Saw blade gets loose after
turning off the motor
Motor does not start
Wrong rotational direction
No motor output, turns off
automatically
Burns on the cutting
surface
Possible cause
Fastening nut tightened insufficiently
failure main fuse
extension cable defect
connection to the motor or switch defect
Changed phase
cross section of extension cable is too
low
overload by dull saw blade
Dull saw blade
wrong saw blade
www.scheppach.com
• These statements only apply to devices installed
and sold in the countries of the European Union
and which are subject to the European Directive
2012/19/EU. In countries outside the European Un-
ion, different regulations may apply to the disposal of
waste electrical and electronic equipment.
Help
Tighten fastening nut, M20 left-handed
thread
Check the mains fuse
Replace the extension cable
Have to be checked by an electrician
Change the phase (see fig. 10)
See "electrical connection"
Insert a sharpened saw bladen
Insert a sharpened saw blade
Insert correct saw blade
GB | 29