Maintenance
Interval
Annual
Annually
After 24 months (2 years)
If you want to arrange maintenance or repair of the proportional metering unit
by Ecolab, the proportional metering unit must be sent to Ecolab Engineering.
Ä Chapter 1.5 'Repairs/returns to Ecolab Engineering GmbH' on page 12
9.5
Maintenance work
Prior to long downtimes (recommended >24 hours) of the metering system, the
metering unit must be flushed as a maintenance routine.
The solution in the proportional dosing unit must be flushed completely with
water (see in acc. with
on page 55 and
prevents damage to the components on the dosing unit that can arise through
extended contact and an absence of throughput.
Manufacturer documentation
Before carrying out any maintenance work on supplier components, also
observe the information in the manufacturer's documentation.
C 'Component operating manuals' on page 102
9.5.1
MiniPlus FF06 fine filter
Rinse filter
Non-compliance can lead to filter clogging. Pressure drop and decreasing water flow
n
are the result.
The filter screens are made of stainless steel. Red coating due to rust from the pipes
n
has no influence on function and filter effect.
Filtered water can be removed during rinsing.
If the outlet is open, place a suitable container under the ball valve.
MAN048969, Ver. 5-05.2024
Maintenance work
Pressure relief valve
Check functionality,
Ä 'Check pressure reducer' on page 59
n
disassemble components and check for wear,
n
pressure reducer' on page 60
Ä More information on: Pressure relief valve D06FH [Honeywell]
Suction hose
Replace suction hose
n
Suction lance
Replace suction lance
n
Proportional dosing unit
Replace all seals made from Kalrez
n
Ä Chapter 9.2 'Preparing the station for maintenance'
Ä Chapter 9.3 'Complete service' on page 57 ). This
Ä 'Remove the
58
Personnel
Operator
Operator
Specialist
Specialist
Ä Appendix