Replace the seals of the metering unit
NOTICE!
Do not use tools or metal objects.
Fig. 15: Deform seal
Protective equipment:
To switch the metering pump to a pressure-free state, close the water supply.
1.
Remove the suction hose and the metering unit.
2.
Pull the metering unit downwards from the pump body.
3.
Hold the seal and the metering part between your thumb and index finger; squeeze
4.
the seal toward the opposite side to deform it.
Increase the deformation to grip the seal and then remove it from its recess.
5.
Clean the seal with a cloth or replace it if necessary.
6.
Insert the seal into the recess. Make sure that the seal is not twisted.
7.
Replace the valve and the ribbed end piece.
8.
Assemble metering pump in reverse order to its disassembly.
9.
9.6
Servicing tasks
9.6.1
Metering pump DOSATec D25 RE 09
If you want to arrange maintenance or repair of the proportional metering unit
by Ecolab, the proportional metering unit must be sent to Ecolab Engineering.
Ä Chapter 1.5 'Repairs/returns to Ecolab Engineering GmbH' on page 12
Manufacturer documentation
Also observe the exploded drawings in the manufacturer's
documentation.