Required diameters of the injector nozzles
according to burner and gas types
Gas type
Nominal supply pressure
(1 mbar 10.197mm H
Burner types*
Economy burner
Standard burner
Rapid burner
Wok burner
*
For burner types of your hob model, see "Properties and configuration of the appliance"
After completing the injector change
• Check the replaced injector nozzle for leaks, e.g. by proceeding
in the same way as described for checking the gas connection in
the corresponding chapter, but never with a flame!
• Have the minimum level setting adjusted to the gas type
as described in the following section.
Natural gas (NG)
G20 / 20 mbar
O)
2
0.72 mm
0.97 mm
1,15 mm
1,30 mm
Fitting and Installation
Liquefied petroleum gas (LPG)
G30 / 28-30 mbar
G31 /
37 mbar
Injector nozzle diameter
0.50 mm
0,65 mm
0,85 mm
0,90 mm
G30 / 50 mbar
0.45 mm
0,60 mm
0,75 mm
0.80 mm
65