Causes of faults and remedies
...
General
Status Code
0x22
0x23
0x24
0x25
0x26
0x27
0x28
0x29

10.3 Other faults

Fault
Position skips
of the measuring
system
 TR-Electronic GmbH 2013, All Rights Reserved
Page 174 of 175
Name
Description
An invalid reply is received (e.g. reply service
code does not match the request service code, or
Invalid Reply
Received
reply message is shorter than the minimum
expected reply size).
The message received is larger than the receiving
Buffer Overflow
buffer can handle. The entire message was
discarded.
Message Format
The format of the received message is not
Error
supported by the server.
The Key Segment that was included as the first
segment in the path does not match the
Key Failure in path
destination module. The object specific status
indicates which part of the key check failed.
The size of the path which was sent with the
Service Request is either not large enough to
Path Size Invalid
allow the Request to be routed to an object or too
much routing data was included.
Unexpected
An attempt was made to set an attribute that is
attribute in list
not able to be set at this time.
The Member ID specified in the request does not
Invalid Member ID
exist in the specified Class/Instance/Attribute.
Member not
A request to modify a non-modifiable member
settable
was received.
Cause
Remedy
Vibrations, impacts and shocks, e.g. on presses, are
dampened with "shock modules". If the error recurs
Strong vibrations
despite these measures, the measuring system must be
replaced.
Perhaps isolated flanges and couplings made of plastic
Electrical faults
help against electrical faults, as well as cables with twisted
EMC
pair wires for data lines. Shielding and wire routing must
be performed according to the specification.
Extreme axial and
Couplings prevent mechanical stress on the shaft. If the
radial load on the
error still occurs despite these measures, the measuring
shaft may result in a
system must be replaced.
scanning defect.