Causes of faults and remedies

9 Causes of faults and remedies
Fault
Position skips of the
measuring system
 TR-Electronic GmbH 2009, All Rights Reserved
Page 56 of 56
Cause
Strong vibrations
Electrical faults
EMC
- Extreme axial and radial load
on the shaft
TR - ECE - BA - DGB - 0072 - 03
Remedy
Vibrations, impacts and shocks, e.g. on presses, are
dampened with "shock modules". If the error recurs
despite these measures, the measuring system must be
replaced.
Perhaps isolated flanges and couplings made of plastic
help against electrical faults, as well as cables with twisted
pair wires for Clock, Data and Supply. Cable cross
section, cable length, shielding etc. see chapter 7
"Installation / Preparation for commissioning", page 47.
Couplings prevent mechanical stress on the shaft. If the
error still occurs despite these measures, the measuring
system must be replaced.