Herunterladen Inhalt Inhalt Diese Seite drucken

TR-Electronic C 115 Serie Gesamt-Bedienungsanleitung Seite 157

Absolut encoder
Inhaltsverzeichnis

Werbung

Attr.-ID
Access
NV
100
Get
V
101
Set
NV
102
Set
NV
103
Set
NV
104
Set
NV
105
Set
NV
106
Get
V
107
Set
NV
108
Set
NV
109
Set
NV
110
Set
-
111
Set
-
112
Set
V
113
Get
V
114
Get
V
Table 15: Position Sensor, Overview of the instance attributes
1)
This attribute only takes effect after executing service code 0x16 save or attribute 112
Accept Parameter.
2)
This attribute is immediately active and saved.
3)
This attribute is immediately active but not saved to non-volatile memory.
Printed in the Federal Republic of Germany
01/27/2022
Name
Position Value
Extended
Total Measuring
1)
Range
Number of
1)
Revolutions -
Numerator
Number of
1)
Revolutions -
Denominator
Preset Value
2)
Extended
1)
TR-Parameter in use
Temperature Value
Temperature Value
1)
Format
Temperature Low
3)
Limit
Temperature High
3)
Limit
Additional Vendor-
Parameter 1
Additional Vendor-
Parameter 2
Accept Parameter
Encoder Firmware
Number
Encoder Firmware
Version
TR-ECE-BA-DGB-0102 v10
Data type Description
ULINT
Position value, 64 Bit
Total measuring range in
ULINT
steps
Number of revolutions
UDINT
numerator
Number of revolutions
UDINT
denominator
ULINT
Preset value (64 bit)
Defines which scaling
BOOL
parameters are in use
INT
Temperature value
ENGUNIT
Temperature format
Minimum temperature
INT
value
Maximum temperature
INT
value
Reserved for further
UDINT
function
Reserved for further
UDINT
function
Save parameters in non-
USINT
volatile memory
Firmware number of the
STRING
measuring system
Firmware version of the
STRING
measuring system
Default
Page
-
141
16777216
142
4096
143
143
1
0
146
0
147
147
in °C
148
0x1200: °C
0
148
149
0
-
149
149
-
0
149
150
-
-
150
 TR-Electronic GmbH 2013, All Rights Reserved
Page 125 of 175