Never operate the lift with any person or equipment below.
Never exceed the rated lifting capacity.
Always ensure that the mechanical safeties are engaged before any attempt is
made to work on or near the vehicle.
Never leave the lift in an elevated position unless the safeties are engaged.
If an anchor bolt becomes loose or any component of the lift is found to be
defective, DO NOT USE THE LIFT until repairs are made.
8.1 CONTROLS OF LIFT
Figure 30 – CONTROLS OF LIFT
Controls for operating the lift are:
POWER SWITCH (1)
The main switch can be set in two positions:
0 position: the electric circuit is not powered; the switch can be padlocked to prevent the use of
the lift.
1 position: the electric circuit is powered
PLIOT LAMP (2)
It shows that the electric circuit is powered
LIFTING BUTTON (3)
When pressed, the power unit is running and the lift can be raised to a desired height until the
button is released.
REV. 01
RP-TOOLS Werkstatt-Technik
6
2
1
77 / 94
5
3
4