Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection Of The Tubular Motor (Figure K ); Control With 1-Pole Switch (Closer) (Figure L ) - RADEMACHER RolloTube I-line Funk Small Montageanleitung

Duofern-rohrmotoren
Vorschau ausblenden Andere Handbücher für RolloTube I-line Funk Small:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electrical connection of the tubular motor (Figure k )
11
(a)
(b)
(c)
Control with 1-pole switch (closer) (Figure l )
The.radio.tubular.motor.can.be.controlled.locally.by.means.of.connecting.a.1-pole.switch.
(closer).to.the."external switch".conductor..
In doing so, the switching sequence is as follows:
OPEN/STOP/CLOSE/STOP, and so on.
12
(a)
(b)
(c)
Legend
(a) .=. set.button.(11)
(b/d) =.socket.box
(c) . =. Mains.230.V/50.Hz
Pin assignment
(e) .. = . PE.
(f) ..=. N.
(g) .. = . L.
(d)
(h) .. = . external switch.. white.. (not.connected.in.this.example)
(i) ..=. Antenna .
IMPORTANT
. ◆ If.the.external switch (h).lead.is.not.used,.then.it.must.be.connected.to.the.neutral conductor (f).
. (see.fig..k).
(e) (f) (g)
(h)
(i)
Legend
(a) .=. set.button.(11)
(b) .. = . 1-pole.switch
(c) . =. Mains.230.V/50.Hz
(d) .. = . Socket.box
Pin assignment
(e) .. = . PE.
(f) ..=. N.
(g) .. = . L.
(d)
(h) .. = . external switch.. white..*
(i) ..=. Antenna.
.
IMPORTANT
. ◆ If.the."external switch" (h).lead.is.not.used,.then.it.must.be.connected.to.the.neutral conductor (f)
(e) (f) (g)
(h)
(i)
(see.fig..k).
green/yellow
blue
black
violet
green/yellow
blue
black
violet
.
*.maximum.cable.length.between.tubular.motor.and.external.switch.=.10.m
EN