Connect / disconnect the DuoFern central operating unit with the radio code
Button
1.
M
OK
2.
OK
3.a
OK
3.b
M
4.
OK
5.
6.
OK
7.
8.
OK
54
Display
Each.DuoFern.transmitter.that.is.required.for.operation.has.to.be.assigned.to.the.tubular.motor.in.order.that.the.radio.tubular.motor.can.be.
controlled.with.a.DuoFern.transmitter..
1. Select the "Radio Code" menu on the DuoFern central operating unit:
M
. .
Main.menu
..
System.settings
2
. .
Radio.settings
2 . 2
. .
Radio.code
Confirm selection.
Enter the six-character radio code of the DuoFern tubular motor and confirm each figure (see enclosed sticker).
If necessary you can jump back to the previous figure to correct it.
Upon confirmation of the last figure you can activate ...
... connect mode
or
disconnect mode on the radio tubular motor.
Exit the menu.
2 . ,1
Select menu "
Activate function "
The.number.of.logged.on.actuators.is.indicated.on.the.display.(e..g..0.in.the.event.of.initial.installation).
Connect/disconnect" on the central operating unit.
2 . ,1
Connect/disconnect" on the central operating unit.
EN